Hammer mill troubleshooting

Updated on By Moinhos Vieira – technical team

Most hammer mill problems have a simple cause: worn hammers or screen, overfeeding, product moisture, a blocked pipe or a worn sealing rubber. Find the symptom below, see the likely cause and what to do. When the fix involves the rotor, the bearings or the electrical connection, call technical assistance.

Need the part? Request hammers · Request screens

Before any check

Switch the mill off and wait for the rotor to stop completely. Never open the grinding chamber while the mill is running.

Applies to MCS and MCD Series mills. For the MCS 190, contact technical assistance. The MCO Series has its own troubleshooting guide.

  1. The mill is producing less than usual

    Likely cause

    • Worn hammers
    • Worn or clogged screen
    • Mill running with the cyclone closed
    • Blocked pipes
    • Reversed direction of rotation
    • Grinding rotor turning without its key

    What to do

    • Turn or replace the hammers.
    • Replace the worn or clogged screen (screens for mills).
    • Keep the cyclone open while grinding and close it only to change the bag.
    • Check and clean the pipes.
    • Reversed rotation: an industrial electrician must correct the motor connection.
    • Rotor without its key: switch the mill off and call technical assistance.
  2. The mill chokes or blows product out of the air vent

    Likely cause

    • Overfeeding
    • Product too moist
    • Worn hammers or screens
    • Altered air flow in the pipe or cyclone

    What to do

    • Feed the mill gradually: the product must enter together with the air the mill draws in.
    • Check the moisture of the product.
    • Turn or replace the hammers and replace the screen if it is worn or clogged.
    • Check and clean the pipe and the cyclone.
  3. Product builds up in the grinding chamber

    Likely cause

    • Product too moist
    • Loss of pressure in the air flow

    What to do

    • Check the moisture of the product.
    • Check the air outlet at the cyclone and the bag filter.
  4. The mill vibrates too much

    Likely cause

    • Rotor imbalance

    What to do

    • Check that the pairs of hammers, pins and spacers have the same weight.
    • If strong vibration starts right after replacing or turning the hammers, switch the mill off and call technical assistance.

    Work for a technician: call technical assistance.

  5. Metal knocking noise inside the mill

    Likely cause

    • Foreign object (metal, stone, etc.) inside the grinding chamber

    What to do

    • Switch the mill off as soon as possible.
    • Open the grinding chamber only when the rotor has stopped completely, and remove the object.
    • If the hammers, screen or rotor are damaged, call technical assistance.
  6. The particle size of the ground product has changed

    Likely cause

    • Worn screen guide sealing rubber
    • Damaged screen

    What to do

    • Replace the rubber (see the guide).
    • Check the screen and replace it if it is damaged.
  7. Product leaks through the grinding chamber door

    Likely cause

    • Worn door sealing rubber

    What to do

  8. Noise from the grinding chamber

    Likely cause

    • Grinding rotor turning without its key

    What to do

    • Switch the mill off and call technical assistance.

    Work for a technician: call technical assistance.

  9. Bearing noise or seized shaft

    Likely cause

    • Bearing damaged by dirt or a foreign object

    What to do

    Work for a technician: call technical assistance.

  10. Belt noise

    Likely cause

    • Loose belts

    What to do

  11. The motor hums but does not turn

    Likely cause

    • Wrong electrical connection of the motor
    • Supply voltage

    What to do

    • Switch the mill off and have an industrial electrician check the motor connection and the supply voltage.

    Work for a technician: call technical assistance.

  12. The rotor will not come off the shaft

    Likely cause

    • Lack of grease on the coupling between shaft and rotor

    What to do

    • Do not force the parts: call technical assistance.

    Work for a technician: call technical assistance.

Technical support

Request technical support

Tell us the mill's status and what is happening. If the mill is stopped, select "Stopped (urgent)".

  • A stopped mill gets priority
  • Support from the factory team
  • Photos help: send them via WhatsApp with your request code

Prefer to talk?

Mon–Thu, 8am–5pm · Fri, 8am–4pm (Brazil time)

Only name, email and phone are required (*). Everything else is optional and helps us respond faster.

What is the mill's status?

To send photos, send them via WhatsApp with your request code.

With country and area code.

We use the data in this form to answer your request and prepare our sales response. If you accepted statistics or marketing cookies, the pages you visited on this site will be linked to your request. Learn more in our Privacy notice.

Chat on WhatsApp

Before opening WhatsApp, leave your name and your number. The right team will receive your request with a code.

We use the data in this form to answer your request and prepare our sales response. If you accepted statistics or marketing cookies, the pages you visited on this site will be linked to your request. Learn more in our Privacy notice.